Over the years SPF Corporation of America has developed a patented and highly successful system used to prevent corrosion in FGD plants. We have a lining system that utilizes a thin layer of highly corrosion resistant metal bonded to a relatively inexpensive carbon steel substrate. This process of applying the highly corrosion resistant metal to the inexpensive substrate is known as our patented SUN Z-R cladding system.
|
|
|
It allows us to clad both weld compatible metals such as nickel based alloys with carbon steels and non-weld compatible metals with each other such as titanium with carbon steel. This technique allows the cost effective use of both relatively high cost alloy metals and relatively low cost carbon steel.
We can supply both retrofit for existing FGD systems as well as new
construction for new plants. Our system is very easy to install with relatively
very little skilled labor required.
For retrofit systems we use the so called Overlap Panel
design. More details and illustrations can be found on the corresponding page.
For new construction we use the so called Batten Bar
design. Once again, more details can be found on the corresponding page.
Both systems are completely completely customizable and are supplied as a
elementary "puzzle" to be assembled on site.
Since the first installation in 1984, over 1,000,000 sq. ft. of FGD ductwork,
chimney liners and absorbers have been protected with our SUN
Z-R cladding system as can be seen in the table below.
|
UTILITY |
PLANT/LOCATION |
COMPONENT |
S.F. AREA |
INSTALLATION
DATE |
Hua
Yang Electric Power Co., Ltd.
| Hua Yang Electric Power Plant, Xiamen, China |
Chimney Liner |
300,000 |
December |
1998 |
KOA
Oil Company, IPP Project |
KOA Oil Plant, Osaka, Japan |
Absorber Tower |
3,100 |
July |
1997 |
Formosa
Plastics Corporation |
Taiwan 6th Naphtha Complex, Kaohsiung, Taiwan |
Chimney Liner |
450,000 |
June |
1997 |
Paiton
Private Power |
Paiton Generating Station, East Java, Indonesia |
Bypass Duct Floor |
125,000 |
September |
1997 |
Big
Rivers Electric Corp |
Green Station, Sebree, KY |
Chimney Liner |
1,200 |
April |
1996 |
Old
Dominion Electric Corp |
Clover, Unit 2, Clover, VA |
Outlet Duct |
26,000 |
July |
1995 |
Big
Rivers Electric Corp |
D.B. Wilson Station, Centertown, KY |
Outlet Duct |
6,000 |
April |
1994 |
Old
Dominion Electric Corp |
Clover, Unit 2, Clover, VA |
Chimney Liner |
26,000 |
February |
1994 |
Kentucky
Utilities |
E.W. Brown Station, Begin, KY |
Chimney Breeching |
700 |
October |
1993 |
Old
Dominion Electric Corp |
Clover, Unit 1, Clover, VA |
Chimney Liner |
26,000 |
August |
1993 |
Big
Rivers Electric Corp |
D.B. Wilson Station, Centertown, KY |
Outlet Duct |
6,200 |
April |
1993 |
Big
Rivers Electric Corp |
D.B. Wilson Station, Centertown, KY |
Outlet Duct |
9,000 |
October |
1992 |
City
of Springfield |
Dahlman Station, Springfield, IL |
Inlet Duct |
700 |
April |
1989 |
Big
Rivers Electric Corp |
Green Station, Unit 2, Sebree, KY |
Chimney Liner |
16,000 |
March |
1989 |
Big
Rivers Electric Corp |
D.B. Wilson Station, Centertown, KY |
Outlet Duct |
3,500 |
October |
1988 |
Cooperative
Power Assoc. |
Coal Creek, Unit 2, Underwood, ND |
Outlet Mixing Zone |
4,000 |
April |
1988 |
Big
Rivers Electric Corp |
Green Station, Unit 1, Sebree, KY |
Chimney Liner |
16,000 |
November |
1987 |
Cooperative
Power Assoc. |
Coal Creek, Unit 1, Underwood, ND |
Outlet Mixing Zone |
4,000 |
October |
1987 |
Potomac
Electric |
Dickerson, Units 1, 2, 3, Washington, D.C. |
Outlet Common Header |
1,500 |
September |
1987 |
|
|
Duct Floor |
|
|
|
Potomac
Electric |
Dickerson, Units 1, 2, 3, Washington, D.C. |
Outlet "
" |
1,750 |
October |
1986 |
Potomac
Electric |
Dickerson, Units 1, 2, 3, Washington, D.C. |
Outlet "
" |
67 |
October |
1986 |
Louisville
Gas & Electric Co. |
Millcreek, Unit 4, Louisville, KY |
Inlet Quench |
850 |
March |
1986 |
Potomac
Electric |
Dickerson, Units 1, 2, 3, Washington, D.C. |
Scrubber Liquid Recirc. |
Various Dia. |
March |
1986 |
|
|
Piping |
|
|
|
Allegheny
Power |
Pleasants, Unit 2, Willow Island, WV |
Chimney Liner |
280 |
September |
1985 |
Potomac
Electric |
Dickerson, Units 1, 2, 3, Washington, D.C. |
Outlet Louver Damper |
Sections |
September |
1985 |
Potomac
Electric |
Dickerson, Units 1, 2, 3, Washington, D.C. |
Chimney Access Doors |
(3) 24" x 36" |
September |
1985 |
Potomac
Electric |
Dickerson, Units 1, 2, 3, Washington, D.C. |
Venturi Scrubber |
(3) 18"E
x 30' |
September |
1985 |
|
|
Downcomer Pipes |
|
|
|
Texas
Utilities |
Martin Lake, Unit 3, Martin Lake, TX |
Inlet Quench |
300 |
December |
1984 |
|
As can be seen from above we have extensive experience in installations of
every size imaginable and each system is custom engineered to best suit the
customer requirements.
|
|
|
SPF Corporation of America:
|
Telephone |
(713) 856-8855 |
Fax |
(713) 856-8834 |
Postal Address |
6529 Cunningham Rd. Ste 2105
Houston, TX 77041, U.S.A. |
eMail |
|
Web Address |
|
|
|
|
SPF Europe BV:
|
Telephone |
31 455 23-1474 |
Fax |
31 455 23-0470 |
Postal Address |
De Koumen 30, 6433 KD Hoensbroek, The Netherlands |
eMail |
|
Web Address |
|
|
|
|
SPF Company LTD.:
|
Telephone |
81 52 871-4121 |
Fax |
81 52 872-1397 |
Postal Address |
5-1, Horita Doori, Mizuho-Ku, Nagoya, 467-0862, Japan |
eMail |
|
Web Address |
|
|
|
|
|
|